RadeLauncher.exe Remains Active for Five Minutes when Session is Closed

RadeLauncher.exe remains active for five minutes when session is closed.

Cause

The Offline Plug-in version 5.2 has introduced a new feature which keeps the ICA session active to be re-used within five minutes to increase second time launch performance. When you exit a streamed application, RadeLauncher.exe remains in use, keeping the session active.

Resolution

This timeout is configurable in the registry and the default timeout value is 5 minutes.  Entering a value of 0 reverts to the behavior of version 5.1, allowing the session to terminate without a delay.

On 32-bit Windows:

HKLM\Software\Citrix\Rade\
Value Name: SandboxStatusMonitorPeriod
Value Type: REG_DWORD
Value Data: Enter a non-negative integer in minutes (a value of 0 causes the session to terminate without delay)

On 64-bit Windows:

HKLM\Software\Wow6432Node\Citrix\Rade\
Value Name: SandboxStatusMonitorPeriod
Value Type: REG_DWORD

For more information and the complete CTX Article please click here